Powerline tools

  • Aerial Cable Stringing Block Four Sheaves Combined Block

    Aerial Cable Stringing Block Four Sheaves Combined Block

    Technical Data Four Sheaves Combined Block Uses : To string the optical cables below 22mm or the cables below 60mm.Feature :Adopts four sheaves structure, bend radius. Model Outline Size(mm) Rated Load (KN) Bend Radius Weight (kg) SHZHD10 760X120X480 10 R570 23.5
  • Four Sheaves Combined Block Aerial Cable Stringing Block

    Four Sheaves Combined Block Aerial Cable Stringing Block

    Technical Data Four Sheaves Combined Block Uses : To string the optical cables below 22mm or the cables below 60mm.Feature :Adopts four sheaves structure, bend radius. Model Outline Size(mm) Rated Load (KN) Bend Radius Weight (kg) SHZHD10 760X120X480 10 R570 23.5
  • Optical Fiber Cable Tools Four Sheaves Combined Block Aerial Cable Stringing Block

    Optical Fiber Cable Tools Four Sheaves Combined Block Aerial Cable Stringing Block

    Technical Data Four Sheaves Combined Block Uses : To string the optical cables below 22mm or the cables below 60mm.Feature :Adopts four sheaves structure, bend radius. Model Outline Size(mm) Rated Load (KN) Bend Radius Weight (kg) SHZHD10 760X120X480 10 R570 23.5
  • Four Sheaves Combined Cable Pulling Conductor OPGW Pulley Block

    Four Sheaves Combined Cable Pulling Conductor OPGW Pulley Block

    Technical Data Four Sheaves Combined Block Uses : To string the optical cables below 22mm or the cables below 60mm.Feature :Adopts four sheaves structure, bend radius. Model Outline Size(mm) Rated Load (KN) Bend Radius Weight (kg) SHZHD10 760X120X480 10 R570 23.5
  • Power Line Tool Four Sheaves Combined Block

    Power Line Tool Four Sheaves Combined Block

    Technical Data Four Sheaves Combined Block Uses : To string the optical cables below 22mm or the cables below 60mm.Feature :Adopts four sheaves structure, bend radius. Model Outline Size(mm) Rated Load (KN) Bend Radius Weight (kg) SHZHD10 760X120X480 10 R570 23.5
  • Fiberglass Telescopic Electroscope Electronic Test Pen

    Fiberglass Telescopic Electroscope Electronic Test Pen

    Technical Data Electroscope Uses:It Is used to check whether the high voltage line and equipment have electricity,so as to ensure the safety of the staff. Model Rated Voltge(KV) Effective Insulation Length(mm) Extension(mm) Constriction(mm) YDB-10 10 90 1100 230 YDB–35 35 1300 1600 260 YDB-110 110 1300 1600 400 YDB-220 220 2000 3100 460 YDB-330 330 4000 4500 1000 YDB-550 500 7000 7500 1500
  • Fiberglass Telescopic Electroscope Electronic Test Pen

    Fiberglass Telescopic Electroscope Electronic Test Pen

    Technical Data Electroscope Uses:It Is used to check whether the high voltage line and equipment have electricity,so as to ensure the safety of the staff. Model Rated Voltge(KV) Effective Insulation Length(mm) Extension(mm) Constriction(mm) YDB-10 10 90 1100 230 YDB–35 35 1300 1600 260 YDB-110 110 1300 1600 400 YDB-220 220 2000 3100 460 YDB-330 330 4000 4500 1000 YDB-550 500 7000 7500 1500
  • Fiberglass Electroscope Electronic Test Pen

    Fiberglass Electroscope Electronic Test Pen

    Technical Data Electroscope Uses:It Is used to check whether the high voltage line and equipment have electricity,so as to ensure the safety of the staff. Model Rated Voltge(KV) Effective Insulation Length(mm) Extension(mm) Constriction(mm) YDB-10 10 90 1100 230 YDB–35 35 1300 1600 260 YDB-110 110 1300 1600 400 YDB-220 220 2000 3100 460 YDB-330 330 4000 4500 1000 YDB-550 500 7000 7500 1500
  • High Voltage Electronic Test Pen

    High Voltage Electronic Test Pen

    Technical Data Electroscope Uses:It Is used to check whether the high voltage line and equipment have electricity,so as to ensure the safety of the staff. Model Rated Voltge(KV) Effective Insulation Length(mm) Extension(mm) Constriction(mm) YDB-10 10 90 1100 230 YDB–35 35 1300 1600 260 YDB-110 110 1300 1600 400 YDB-220 220 2000 3100 460 YDB-330 330 4000 4500 1000 YDB-550 500 7000 7500 1500
  • 110KV High Voltage Retractable Electroscope

    110KV High Voltage Retractable Electroscope

    Technical Data Electroscope Uses:It Is used to check whether the high voltage line and equipment have electricity,so as to ensure the safety of the staff. Model Rated Voltge(KV) Effective Insulation Length(mm) Extension(mm) Constriction(mm) YDB-10 10 90 1100 230 YDB–35 35 1300 1600 260 YDB-110 110 1300 1600 400 YDB-220 220 2000 3100 460 YDB-330 330 4000 4500 1000 YDB-550 500 7000 7500 1500
  • 110KV High Voltage Telescopic Electroscope

    110KV High Voltage Telescopic Electroscope

    Technical Data Electroscope Uses:It Is used to check whether the high voltage line and equipment have electricity,so as to ensure the safety of the staff. Model Rated Voltge(KV) Effective Insulation Length(mm) Extension(mm) Constriction(mm) YDB-10 10 90 1100 230 YDB–35 35 1300 1600 260 YDB-110 110 1300 1600 400 YDB-220 220 2000 3100 460 YDB-330 330 4000 4500 1000 YDB-550 500 7000 7500 1500
  • Double Sided Sleeve Wrench Fasten Tower Anchor Bolts Socket Wrench

    Double Sided Sleeve Wrench Fasten Tower Anchor Bolts Socket Wrench

    Uses: Used to fasten the tower anchor bolts, torque,not easy to loose.